LTV / Commercial / Tractor
When you need powerful starting ability, and dependable lasting power, Centennial Commercial batteries rise to the challenge. Centennial Commercial batteries are built tough to
meet or exceed your most demanding requirements.
From commercial trucks to heavy duty equipment, we have the power for the long haul! We offer a complete line of heavy duty batteries to fit your application and get the job done. Available in low maintenance or completely maintenance free. NEVER ADD WATER! Our Products
|
| Light Truck and Van Series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCI GROUP SIZE | CENTENNIAL PART No. | CCA | RC minutes @ 25 amps | CA / MCA | HCA | VOLTAGE | LENGTH | WIDTH | HEIGHT | |||
| 34/78 | 75DT-LTV | 850 | 120 | 1065 | 1225 | 12 | 10 7/8 | 7 | 8 | |||
| 24 | 24LTV | 800 | 120 | 1000 | 1150 | 12 | 10 13/16 | 6 13/16 | 8 13/16 | |||
| 24F | 24FLTV | 800 | 120 | 1000 | 1150 | 12 | 10 13/16 | 6 13/16 | 8 13/16 | |||
| 27 | 27LTV | 800 | 160 | 1000 | 1150 | 12 | 12 1/16 | 6 13/16 | 8 7/8 | |||
| 27F | 27FLTV | 800 | 160 | 1000 | 1150 | 12 | 12 1/16 | 6 13/16 | 8 7/8 | |||
| 65 | 65LTV | 850 | 160 | 1065 | 1225 | 12 | 11 7/8 | 7 1/2 | 7 5/8 | |||
| 78 | 78LTV | 850 | 140 | 1065 | 1225 | 12 | 10 7/8 | 7 | 7 5/16 | |||
| CCA - | Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell | |||||||||||
| RC - | Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell. | |||||||||||
| CA - | Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| MCA - | Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| HCA - | Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell |
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development. |
||||||||||
| 12 Volt Severe Condition Series - Maintenance Free | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCI GROUP SIZE | CENTENNIAL PART No. | CCA | RC minutes @ 25 amps | CA / MCA | HCA | VOLTAGE | LENGTH | WIDTH | HEIGHT | |||
| 31AP | C-31-10APMF | 1000 | 210 | 1250 | 1440 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-10STMF | 1000 | 210 | 1250 | 1440 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31AP | C-31-7APMF | 800 | 190 | 1000 | 1150 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-7STMF | 800 | 190 | 1000 | 1150 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 4D | C-4DMF | 1000 | 300 | 1250 | 1440 | 12 | 20 3/4 | 8 3/4 | 9 7/8 | |||
| 8D | C-8DMF | 1200 | 430 | 1500 | 1725 | 12 | 20 3/4 | 11 1/8 | 9 7/8 | |||
| 8D | C-8DHMF | 1350 | 440 | 1690 | 1945 | 12 | 20 3/4 | 11 1/8 | 9 7/8 | |||
| CCA - | Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell | |||||||||||
| RC - | Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell. | |||||||||||
| CA - | Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| MCA - | Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| HCA - | Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell |
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development. |
||||||||||
| 12 Volt Heavy Duty Commercial | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCI GROUP SIZE | CENTENNIAL PART No. | CCA | RC minutes @ 25 amps | CA / MCA | HCA | VOLTAGE | LENGTH | WIDTH | HEIGHT | |||
| 29NF | C-29NF | 420 | 100 | 525 | 605 | 12 | 13 | 5 /1/2 | 8 5/16 | |||
| 30H | C-30H | 800 | 170 | 1000 | 1150 | 12 | 13 1/2 | 6 13/16 | 9 1/4 | |||
| 31AP | C-31-10AP | 1100 | 200 | 1375 | 1580 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-10ST | 1100 | 200 | 1375 | 1580 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31AP | C-31-9AP | 975 | 190 | 1220 | 1405 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-9ST | 975 | 190 | 1220 | 1405 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31AP | C-31-8AP | 800 | 180 | 1000 | 1150 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-8ST | 800 | 180 | 1000 | 1150 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31AP | C-31-7AP | 700 | 160 | 875 | 1005 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 31STUD | C-31-7ST | 700 | 160 | 875 | 1005 | 12 | 13 | 6 13/16 | 9 7/16 | |||
| 4D | C-4D | 1100 | 325 | 1375 | 1580 | 12 | 20 3/4 | 8 3/4 | 9 7/8 | |||
| 50 | C-50 | 600 | 108 | 750 | 860 | 12 | 13 1/2 | 5 | 10 | |||
| 53 | C-53 | 350 | 85 | 440 | 505 | 12 | 13 | 4 11/16 | 8 1/4 | |||
| 8D | C-8D | 1200 | 400 | 1500 | 1725 | 12 | 20 3/4 | 11 1/8 | 9 7/8 | |||
| 8D | C-8D-BT | 1200 | 400 | 1500 | 1725 | 12 | 20 3/4 | 11 1/8 | 9 7/8 | |||
| 8D | C-8DH | 1400 | 450 | 1750 | 2010 | 12 | 20 3/4 | 11 1/8 | 9 7/8 | |||
| CCA - | Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0° F at a voltage above 1.2 v/cell | |||||||||||
| RC - | Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80° F and maintain a voltage above 1.75 v/cell. | |||||||||||
| CA - | Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| MCA - | Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32° F at a voltage above 1.2 v/cell | |||||||||||
| HCA - | Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 80° F at a voltage above 1.2 v/cell |
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development. |
||||||||||
| 6 Volt Heavy Duty Commercial | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCI GROUP SIZE | CENTENNIAL PART No. | CCA | RC minutes @ 25 amps | CA / MCA | HCA | VOLTAGE | LENGTH | WIDTH | HEIGHT | |||
| 1 | C-1 | 575 | 150 | 720 | 830 | 6 | 9 1/8 | 7 1/8 | 8 3/4 | |||
| 2 | C-2 | 625 | 160 | 780 | 895 | 6 | 10 3/8 | 7 1/8 | 8 3/4 | |||
| 2E | C-2E | 615 | 185 | 770 | 885 | 6 | 9 7/16 | 4 1/8 | 9 1/8 | |||
| 3EH | C-3EH | 850 | 280 | 1065 | 1225 | 6 | 19 5/16 | 4 3/8 | 9 13/16 | |||
| 4 | C-4 | 1000 | 310 | 1250 | 1440 | 6 | 13 1/8 | 7 1/8 | 9 3/8 | |||
| 4EH | C-4EH | 930 | 320 | 1165 | 1340 | 6 | 19 5/16 | 5 | 9 13/16 | |||
| 5D | C-5D | 850 | 280 | 1065 | 1225 | 6 | 13 3/4 | 7 1/8 | 9 3/8 | |||
| 7D | C-7D | 950 | 360 | 1190 | 1370 | 6 | 16 1/4 | 7 1/8 | 9 3/8 | |||
|
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development and we reserve the right to change design, or specifications or pricing at any time, without notice and without incurring obligation. |
||||||||||||
| CCA - | Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| CA - | Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| MCA - | Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| HCA - | Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| RC - | Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell. | |||||||||||
| 12 Volt Commercial Tractor | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCI GROUP SIZE | CENTENNIAL PART No. | CCA | RC minutes @ 25 amps | CA / MCA | HCA | VOLTAGE | LENGTH | WIDTH | HEIGHT | |||
| 3EE | C-3EE | 425 | 115 | 530 | 610 | 12 | 19 15/16 | 4 3/8 | 8 7/8 | |||
| 3ET | C-3ET | 460 | 120 | 575 | 660 | 12 | 19 5/16 | 4 3/8 | 9 13/16 | |||
| 4DLT | C-4DLT | 1000 | 240 | 1250 | 1440 | 12 | 20 | 8 3/16 | 7 15/16 | |||
| 16TF | C-16TF | 640 | 250 | 800 | 920 | 12 | 16 9/16 | 7 1/8 | 11 1/8 | |||
| 17TF | C-17TF | 510 | 120 | 640 | 735 | 12 | 17 1/16 | 6 15/16 | 7 15/16 | |||
| 22NF | C-22NF | 390 | 70 | 490 | 565 | 12 | 9 7/16 | 5 1/2 | 8 15/16 | |||
| U1L | C-U1L-4 | 190 | 30 | 240 | 275 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
| U1R | C-U1R-4 | 190 | 30 | 240 | 275 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
| U1L | C-U1L-5 | 250 | 35 | 315 | 360 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
| U1R | C-U1R-5 | 250 | 35 | 315 | 360 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
| U1L | C-U1L-6 | 330 | 40 | 415 | 475 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
| U1R | C-U1R-6 | 330 | 40 | 415 | 475 | 12 | 7 3/4 | 5 3/16 | 7 5/16 | |||
|
The product descriptions and specifications were correct at the time this material was being prepared for printing. Our policy is one of continuous development and we reserve the right to change design, or specifications or pricing at any time, without notice and without incurring obligation. |
||||||||||||
| CCA - | Cold Cranking Amps - The discharge load in amperes which a new, fully chargedbattery can maintain for 30 seconds at 0 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| CA - | Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| MCA - | Marine Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| HCA - | Hot Cranking Amps - The discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32 degrees farenheit at a voltage above 1.2 v/cell | |||||||||||
| RC - | Reserve Capacity - The number of minutes a battery can be discharged at the specified rate (25, 56 or 75 amps) at 80 degrees farenheit and maintain a voltage above 1.75 v/cell. | |||||||||||